GFC400, 1000Vdc, 400 Amp, PyroTactor (HV Fuse + Contactor)
Bi-Directional High Voltage Battery Disconnect and Contactor Combination with Passive & Active Triggering.
| Specifications | |
| Rated Voltage | 1000 V |
| Continuous Current Rating at 85 °C | 400 A |
| Max Interrupt Current at 1000 V & 27 µH-Fuse | 4000 A |
| Max Interrupt Current at 500 V & 27 µH-Fuse | 12000 A |
| Max Interrupt Current at 1000 V & 27 µH-Contactor | 1000 A |
| Max Resistance before opening | .250 mΩ |
| Max Clear Time | 3 ms |
| Operating Temperature | -40 °C ~ 85 °C |
| Weight | < 600 grams |
| Triggering Current Tolerance | ± 150 A |
| Minimum Dielectric After Trigger | 5 MΩ |
Railway and Metro system, Energy Storage System, Electric Vehicles, Two-wheeled & Three wheeled electric motorcycles and bicycles, Automated Guided Vehicles, Aerospace Devices, Civil ships and Military ships, Power Electronics system of industrial automation equipment and industrial communications Equipment such as satellites and radars etc.
| GFC400 INITIATOR DATA | |
| Qualified Acc. to | LV 16 & USCAR |
| Initiator Resistance | ≥ 1.7 Ω and ≤ 2.5 Ω |
| Triggering Pulse Current | ≥ 1.75 A / 0.5 mS or ≥ 1.2A / 2.0 mS |
| No-Triggering Current | ≤ 0.4 A or ≤ 5.0A / ≤ 4 μS |
| Diagnostic Current | ≤ 100 mA |
GL250HAANA High Voltage DC Contactor
GLK20AB High Voltage DC Contactor
G8SF 15kV, SPDT High Voltage Relay
GL150HTANA High Voltage DC Contactor
G43A334 10kV, SPST-NO High Voltage Relay
GL100ACANB High Voltage DC Contactor
Gigavac GX16CEC 24Vdc 600A DC Contactor
GLK20AC High Voltage DC Contactor
GL100ABANB High Voltage DC Contactor
Gigavac GXC16CEBV 800Vdc 600A DC Contactor 