MP – Mechanical Products
MP was founded in 1940. In its early years, MP focused on developing innovative circuit breaker designs for the aerospace industry, which helped MP become the exclusive supplier of all flight-critical circuit breakers for the Apollo and Space Shuttle programs. In the mid-1950s, MP began developing circuit breakers for commercial applications. MP’s management team purchased the company in 1998. Today, MP remains a privately held company that continues to strengthen its product portfolio of thermal circuit protection devices by offering innovative solutions for the most demanding applications.
[popup_anything id=”11261″]
Circuit Breakers: 0.5 – 300A Switchable & Push-to-Reset Hi-Amp Type 1 & 3
Series | Series 16 | Series 16 | Series 16 | Series 17 | Series 18 | Series 19 | Series 32 | |
Models | 1601, 1611, 1681 | 1600, 1604, 1610, 1680 | 1648 | 171, 174, 175, 176 | 1800, 1801, 1810, 1811 | 19A, 19M | 321, 322, 323 | |
Features | Low Amp. Robust design. Push-to-Reset, supplementary protector. Various mounting styles and termination options available. UL1500, Ignition Protected. Qualified for Resistive & Motor applications. Cadmium free contacts. | Mid Amp. Robust Design. Push-to-Reset, supplementary protector. Various mounting styles and termination options available. UL1500 Ignition Protected. Qualified for Resistive & motor applications. Cadmium free contacts. | Hi Amp. Robust Design. Push-to -Reset, supplementary protector. Various mounting styles with #10-32 screw terminals standard. UL1500 Ignition Protected. Cadmium free contacts. | Hi-Amp, dust & waterproof ignition protected, type I III & III (PTT) circuit breaker. Standard designs offered thru 300A in panel and surface mount versions. Options include new easy access 1/4” & 3/8” stainless terminals & hardware.
Patented. LED TripIDTM accessory. |
Weatherproof, ignition proof, available as a Push-to-Reset protector. Designed for harsh environments as tested to ABYC, USCG, SAE, UL & Mil Stds requirements. UL1500 Ignition Protected. | Hi-Amp, superior dust & waterproof rating, Ignition protected, Type I &
Type III circuit breaker. Fit, form & function to traditional offerings, with expanded ratings through 200 Amps. Options include mounting plate to fit competitive 175 – 200A panel cutout stainless hardware, and patent pending TripIDTM. |
Smallest Push-to-Reset breaker available in 3 – 40 Amps. Various mounting and termination options. Ignition Protected. Cadmium Free contacts. | |
Current Ratings | 0.5 – 4.5 Amperes | 5 – 35 Amperes | 40 – 70 Amperes | 25 – 300 Amperes | 2 – 70 Amperes | 25 – 200 Amperes | 3 – 50 Amperes | |
Voltage
Ratings |
250VAC / 50VDC | 250VAC / 50VDC (5 – 25A)
250VAC / 32VDC (26 – 35A) |
250VAC / 50VDC | 48VDC (25 – 150A)
30VDC (175 – 200A) 14VDC (225 – 300A) |
120VAC / 32VDC | 30VDC | 14VDC (Type I & II) 28VDC (Type III) | |
Calibration @ 25OC (percent of rating) | =< 1A 100% Hold, 145% Trip > 1A 100% Hold, 135% Trip | 100% Hold, 135% Trip | 100% Hold, 140% Trip | 100% Hold, 135% Trip | 100% Hold, 135% trip
(2-40A, Series 1800 & 1801) 110% Hold, 143% Trip (12.5-70A, Series 1810 & 1811) |
100% Hold, 135% Trip | <5A 100% Hold, 150% Trip =>5A 100% Hold, 135% Trip | |
200% 500% 1000% | 10 – 32 sec | 4 – 15 sec (5-7.5A) 5 – 30 sec (8-35A) | 5 – 30 sec | 10 – 40 sec | 4 – 150 sec (2-40A)
6 – 70 sec (12.5-60A) |
10 – 40 sec | 4 – 40 sec | |
3 – 4.7 sec | 0.5 – 1.8 sec (5-7.5A)
0.5 – 2.8 sec (8-35A) |
0.5 sec – 2.8 sec | 0.4 – 5 sec | 1.2 – 20 sec (2-10A)***
0.6 – 5 sec (12.5-60A)*** |
0.4 – 5 sec | 0.4 – 2.8 sec | ||
2.3 – 4.2 sec** | 0.16 – 0.66 sec (5-7.5A) 0.15 – 0.78 sec (8-35A) | 0.15 – 0.78 sec | 0.09 – 1.2 sec | 0.3 – 2.5 sec (2-40A)
0.1 – 0.7 sec (12.5-60A) |
0.09 – 1.2 sec | 0.12 – 0.7 sec | ||
Short Circuit Interruption | Per UL1077
1,000A @ 250VAC / 50VDC 2,000A @ 120VAC MP Performance Certified 3,000A @ 32VDC |
Per UL1077
1,000A @ 250VAC / 50VDC 2,000A @ 120VAC MP Performance Certified 3,000A @ 32VDC |
Per UL1077
1,000A @ 250VAC / 50VDC 2,000A @ 120VAC MP Performance Certified 3,000A @ 32VDC |
Per SAE J553, J1625, ABYC-E11
3,000A @ 30VDC, Type I (25-150A) 1,500A @ 30VDC, Type I (175-200A) 2,500A @ 14VDC, Type I (225-300A) 3,000A @ 14VDC, Type III (25-200A) 1,500A @ 48VDC, Type III (25-150A) |
Per UL1077
3,000A @ 120VAC / 32VDC (Series 1800, 1801, 1810, 1811) 5,000A @ 32VDC (Series 1810, 1811) |
Per SAE J553, J1625, ABYC-E11
2,500A @ 30VDC, Type I (25-200A) 2,500A @ 14VDC, Type I (25-150A) 1,500A @ 28VDC, Type III (25-150A) 2,500A @ 30VDC, Type III (175-200A) |
Varies by current and voltage. See datasheet | |
Regulatory Approvals | UL, CSA, CCC, VDE (IEC) | UL, CSA, CCC, VDE (IEC) | UL, CSA, CCC | ABYC-E11, IP67, Mil-STD-202, SAE J553, J1171, J1625 | UL1500 | ABYC-E11, IP67, IP69K, Mil-STD-202, SAE J553, J1171, J1625 | SAE J553*, J1171* | |
Motor Load Rated | Yes | Yes | * | N/A | N/A | N/A | N/A |
[popup_anything id=”11261″]
Series | Series 07 | Series 07 | Series 24 | Series 02 | Series 12 | Series 14 | Series 15 | |
Models | 752 | 762, 772 | 2410, 2411, 2420, 2421 | 252, 600, 601 | 1221, 1223, 1224, 1227 | 1400, 1430 1450, 1480, 1490 | 1500, 1530, 1560, 1580 | |
Features | Switchable, Trip Free “Double Break” mechanism, with High Interrupt Capacity. The 752 Push-Pull variants are the smallest UL489 listed molded case circuit breakers available. Suitable for Branch Circuit Protection. Cadmium free contacts. | Switchable Trip Free “double Break” operations gives the Models 762 & 772 up to a 5,000 Amp Interrupt Capacity in a small package size. For 5 – 30 Amps, 0.250” quick connect terminals standard. In 30 – 40 Amps, #10-32 screw terminals are standard. Cadmium free contacts. | Compact Snap-in panel mount, 1 & 2 pole, Power “on/Off” switch with Trip Free Circuit Protection. Options include actuator markings, illuminations, guards, and a splash protector. Switch only versions are available in 1 pole devices, or in one or both poles of a 2 pole device. | Trip Free “Double Break” mechanism with High Interrup capacity. Suitable for branch circuit protection. 0.250” quick connect terminals are standard and #10-32screw terminals at 30 Amps. Cadmium free contacts. | Most economical & compact design, cycling trip free, Pushto-Reset supplementary protector offered in a variety of mounting and termination options. | Compact, economical, Push-to-Reset supplementary protector. Various mounting styles and termination options available. UL1500 ignition protected. Qualified for resistive & motor applications. | Smallest Push-to-Reset breaker available in 3 – 40 Amps. Various mounting and termination options. Ignition Protected. Cadmium Free contacts. | |
Current Ratings | 15 – 20 Amperes | Model 762: 5 – 30 Amperes Model 772: 30 – 40 Amperes | 0.1 – 30 Amperes | 5 – 30 Amperes | 3 – 20 Amperes | 3 – 30 Amperes | 3 – 40 Amperes | |
Voltage Ratings | 120VAC | 277VAC (5-9A)
120VAC (10-30A) 277VAC / 32VDC (30-40A) |
250VAC / 50VDC | 120VAC / 277VAC / 32VDC | 120 / 250VAC / 50VDC | 250VAC / 50VDC | 250VAC / 50VDC | |
Calibration @ 25OC (percent of rating) | 100% Hold, 135% Trip | 100% Hold, 135% Trip | 100% Hold, 135% Trip | 100% Hold, 135% Trip | 100% Hold, 150% Trip | 100% Hold, 135% Trip | 100% Hold, 150% Trip (3-4A)
100% Hold, 135% Trip (5-40A) |
|
200% 500% 1000% | 5-30 sec | 5-20 sec (5-7A)
5-30 sec (8-40A) |
8-40 sec | 5-20 sec (5-7A)
5-30 sec (8-40A) |
4-40 sec | 4-40 sec | 5-40 sec (3-4A & 25-40A) 5-30sec (5-20A) | |
0.5-3.3 sec | 0.5 – 1.9 sec (5-7A)
0.5 – 3.3 sec (8-35A) |
1-3 sec | 0.5 – 1.9 sec (5-7A)
0.5 – 3.3 sec (8-35A) |
0.4-2.8 sec | 0.4-2.8 sec | 0.6-3.3 sec (3-40A) | ||
0.15-0.9 sec | 0.17 – 0.53 sec (5-7.5A) 0.15 – 0.9 sec (8-35A) | 0.2-1 sec | 0.17 – 0.53 sec (5-7.5A) 0.15 – 0.9 sec (8-35A) | 0.12-0.7 sec | 0.12-0.4 sec | 0.15-0.9 sec (3-40A) | ||
Short Circuit Interruption | Per UL489 5,000A @ 120VAC | Per UL1077 5,000A @ 120VAC | Per UL1077
5,000A @ 250VAC 1,000 @ 50VDC |
Per UL489
5,000 @ 120VAC Per UL1077 5,000A @ 277VAC / 32VDC |
Per UL1077
1,000A @ 250VAC 1,000A @ 50VDC |
Per UL1077
1,000A @ 250VAC / 50VDC 3,000A @ 32VDC |
Per UL1077
1,000A @ 250VAC 1,000A @ 50VDC 2,500A @ 32VDC |
|
Regulatory Approvals | UL, CSA, CCC, VDE (IEC) | UL, CSA, CCC, VDE (IEC) | UL, CSA, CCC, VDE (IEC) | UL, CSA, CCC, VDE (IEC) | UL, cUL, CSA, CCC, VDE (IEC) | UL, cUL, CCC, VDE (IEC) | UL, cUL, CSA, CCC*, VDE (IEC) | |
Motor Load Rated | N/A | Yes | Yes | Yes (600, 601) | N/A | Yes | Yes | |
Notes | Vibration:8g
Shock: 25g Corrosion:96hrSalt Spray Humidity:240hr at 95% RH |
Vibration: 8g
Shock:25g Corrosion: 96hr Salt Spray Humidity: 240hr at 95% RH |
Vibration: 8g
Shock: 30g Corrosion: 96hr Salt Spray Humidity: 240hr at 95% RH UL1500 Ignition Protected |
Vibration: 8g
Shock: 25g Corrosion: 96hr Salt Spray Humidity: 240hr at 95% RH |
Vibration: 8g
Shock: 30g Corrosion: 96hr Salt Spray |